The Explorer:
This system is designed for the end user only requiring a minimum power option in a neat package. Available in 3 different versions;
K-EXPLORER-01 inc ePRO PLUS Battery Monitor
K-EXPLORER-02 inc Simarine Battery Monitoring
K-EXPLORER-03 inc Simarine & Individual Load Monitoring
The Explorer 01 for example consists of the following items
Enerdrive ePOWER DC2DC40+ Vehicle/Solar Charger
1 x ePRO Plus Battery Monitor
4x Pre-wired Circuit Breakers for main power equipment
4 x Contura switches for Lights & Auxiliary loads
Pre-wired Battery & Fridge Anderson Plugs
1 x 12v CIG & 1 x Dual 2.4A USB sockets come standard. You can choose a mixture of Twin USB 2.4A Hi Amp sockets to charge your mobile devices or mix it up with 2 x 12v Output Socket. The choice is yours at time of order.
Battery Reset button for kick starting your flat battery from the DC2DC Charger
All Explorer systems are pre-wired by Enerdrive so the only cabling required at installation time is load outputs, battery connection & vehicle/solar/tank inputs
Specifications: SKU K-EXPLORER-01-R
Warranty Period 5 Years
Nominal Voltage 12.8V (125Ah & 200Ah & 300Ah Battery)
Nominal Capacity 125Ah or 200Ah or 300Ah (Batteries)
Cycle Life (DOD – 80% under controlled conditions)≥ 2000 Cycles (125Ah & 200Ah & 300Ah Battery)
Battery Charge Temperature 0 ̴ 45°C (125Ah & 200Ah & 300Ah Battery)
Normal Charge Voltage CV/CC*14.40 ̴ 14.60V (125Ah & 200Ah & 300Ah Battery)
Standby (Float) Voltage 13.50 ̴ 13.80V (125Ah & 200Ah & 300Ah Battery )
Maximum Charge Current 60A @ 25°C for 30mins (125Ah Battery) | 150A @ 25°C for 30mins (200Ah Battery) | 190A @ 25°C for 30mins (300Ah Battery)
Recommended Charge Current for Maximum Life ≤ 40A (125Ah & 200Ah Battery) | 80 ~ 120A(300Ah Battery)
Battery Discharge Temperature -20 ̴ 60°C (125Ah & 200Ah & 300Ah Battery)
Battery Output Voltage Range 11.00 ̴ 14.60V (125Ah & 200Ah & 300Ah Battery)
Maximum Discharge Current100A @ 25°C ± 5°C for 30mins (125Ah Battery) | 200A @ 25°C ± 5°C for 30mins (200Ah Battery) | 250A @ 25˚C ±5˚C for 15 mins(300Ah Battery)
Pulse Discharge Current 450A for 1.0s (125Ah & 200Ah & 300Ah Battery)
Discharge Cut-off Voltage ≤11.20V (125Ah & 200Ah & 300Ah Battery)
Float 13.0V – 13.8V (DC Battery Charger)
Dimensions 440 x 155 x 330mm (Explorer System Overall) | 242 x 172 x 74mm (DC Battery Charger) | 318 x 165 x 215 mm (125Ah Battery) | 505 x 172.5 x 265 mm (200Ah
Voltage 12V (125Ah & 200Ah & 300Ah Battery)
Equalize 15.5V (DC Battery Charger)
Efficiency 95% (DC Battery Charger)
Output System Voltage 12V
Net Weight (kg) 7
Temperature Setting Low/ Normal/ High (Battery Temperature Sensor Standard) (DC Battery Charger)
Charger Mode Output Voltage 13.8V – 15.5V (DC Battery Charger)
Charging Control Three Stages (DC Battery Charger)
DC Output Single (DC Battery Charger)
Selectable Battery Type Gel, AGM, Flooded, Lithium, Program (DC Battery Charger)
Power-System-Series-The-Explorer-Flyer-WEB_2022