The Traveller:
This system is designed for the end user requiring a higher level of power requirements along with AC charging ability. Available in 3 different versions;
K-TRAVELLER-01 inc ePRO PLUS Battery Monitor
K-TRAVELLER-02 inc Simarine Battery Monitoring
K-TRAVELLER-03 inc Simarine & Individual Load Monitoring
The Traveller 01 for example consists of the following items
Enerdrive ePOWER DC2DC40+ Vehicle/Solar Charger
Enerdrive ePOWER 40A AC charger
1 x ePRO Plus Battery Monitor
4x Pre-wired Circuit Breakers for main power equipment
4 x Contura switches for Lights & Auxiliary loads
Pre-wired Battery & Fridge Anderson Plugs (Explorer & Traveller only)
1 x 12v CIG & 1 x Dual 2.4A USB sockets come standard. You can choose a mixture of Twin USB 2.4A Hi Amp sockets to charge your mobile devices or mix it up with 2 x 12v Output Socket. The choice is yours at time of order.
Battery Reset button for kick starting your flat battery from the DC2DC Charger
All Traveller systems are pre-wired by Enerdrive so the only cabling required at installation time is load outputs, battery connection & vehicle/solar/tank inputs
Specifications: SKU K-TRAVELLER-01-R
Warranty Period 5 Years
Nominal Voltage 12.8V (100Ah, 125Ah, 200Ah & 300Ah Battery)
Nominal Capacity 100Ah, 125Ah, 200Ah or 300Ah(Batteries)
Cycle Life (DOD – 80% under controlled conditions) ≥ 2000 Cycles (100Ah, 125Ah, 200Ah & 300Ah Battery)
Battery Charge Temperature 0 ̴ 45°C (100Ah, 125Ah, 200Ah & 300Ah Battery)
Normal Charge Voltage CV/CC* 14.20 ̴ 14.60V (100Ah Battery) | 14.40 ̴ 14.60V (125Ah & 200Ah & 300Ah Battery)
Standby (Float) Voltage 13.50 ̴ 13.80V (100Ah, 125Ah, 200Ah & 300Ah Battery)
Maximum Charge Current 80A @ 25°C for 30mins (100Ah Battery) | 60A @ 25°C for 30mins (125Ah Battery) | 150A @ 25°C for 30mins (200Ah Battery) | 190A @ 25°C for 30mins (300Ah
Recommended Charge Current for Maximum Life ≤ 33A (100Ah Battery) | ≤ 40A (125Ah & 200Ah Battery) | 80 ~ 120A(300Ah Battery)
Battery Discharge Temperature -20 ̴ 60°C (100Ah, 125Ah, 200Ah & 300Ah Battery)
Battery Output Voltage Range 11.00 ̴ 14.60V (100Ah, 125Ah, 200Ah & 300Ah Battery)
Maximum Discharge Current 100A @ 25°C ± 5°C for 30mins (100Ah & 125Ah Battery) | 200A @ 25°C ± 5°C for 30mins (200Ah Battery) | 250A @ 25˚C ±5˚C for 15 mins(300Ah Battery)
Pulse Discharge Current 450A for 1.0s (100Ah, 125Ah, 200Ah & 300Ah Battery)
Discharge Cut-off Voltage ≤11.20V (100Ah, 125Ah, 200Ah & 300Ah Battery)
DC Output Connection Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread (AC Battery Charger)
Output Short Circuit Yes, (with user replaceable fuse/s) (AC Battery Charger)
Dimensions 685 x 155 x 330mm (Traveller System Overall) | 242 x 172 x 74mm (DC Battery Charger) | 295mm x 206mm x 90mm (AC Battery Charger) | 310 x 170 x 225 mm
Power Factor Correction Yes (AC Battery Charger)
Voltage 12V (100Ah, 125Ah, 200Ah & 300Ah Battery)
Selectable Battery Type Gel, AGM, Flooded, Lithium, Program (DC & AC Battery Charger) (AC Battery Charger)
Storage Range (temp) -40° to 70° C (AC Battery Charger)
Power consumption (DC 12V) 700W (Full Load) (AC Battery Charger)
Efficiency 95% (DC Battery Charger)
Standby Current < 2 mA (AC Battery Charger)
LCD Display Charging status, Battery Voltage, Output Current & Fault Codes (AC Battery Charger)
Regulatory Compliance Complies with AS/NZS 60335.2.29 Including Australian deviations (AC Battery Charger)
AC Input Connection IEC with Supplied 1.2M Power Lead (AC Battery Charger)
Operating Range (temp) -20° to 60° C (AC Battery Charger)
Over Charge Yes, unit shutdown (AC Battery Charger)
AC Input Frequency Range 47 – 63 Hz (AC Battery Charger)
Equalize 15.5V (DC Battery Charger) | 16.0 V (AC Battery Charger)
Charger Efficiency > 82% (AC Battery Charger)
AC Input Operating Range 207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) (AC Battery Charger)
Ingress Protection IP32 (Basic drip proof in vertical orientation) (AC Battery Charger)
Float 13.0V – 13.8V (DC Battery Charger) | 13.4 – 13.8 V (AC Battery Charger)
AC Input Voltage 90 to 265 VAC (AC Battery Charger)
DC Output Ground Single Heavy Duty Common Ground Stud (AC Battery Charger)
Battery Temp Sensor Port RJ12 (standard battery temp. sensor supplied) (AC Battery Charger)
Humidity 5-95%, relative humidity non-condensing (AC Battery Charger)
Reverse Polarity Yes, (with user replaceable fuse/s) (AC Battery Charger)
DC Output Single (DC Battery Charger) | Three (1 fully independent, 2 common with diode isolation) (AC Battery Charger)
Over Temperature Protection Yes, unit de-rated and shutdown (AC Battery Charger)
Temperature Setting Low/ Normal/ High (Battery Temperature Sensor Standard) (DC Battery Charger) | Hot, Normal, Cold (no sensor connected) (AC Battery Charger)
Charger Mode Output Voltage 13.8V – 15.5V (DC Battery Charger) | 14.2 – 15.5 V (AC Battery Charger)
Cooling Forced air ventilation (thermo controlled fan) (AC Battery Charger)
Charging Control Three Stages (DC Battery Charger) | Four stages (Bulk/Absorption/Float/Maintenance), Two stages (Bulk/Absorption)Constant Power Supply (Program setti
Output System Voltage 12V
Net Weight (kg) 10.5